Cat5e & Cat6/6A Keystone Jacks

Basic Features:

☆ Significant margin over ANSI/TIA 568-B, ISO/IEC 11801and EN 50173.
☆ Twists are maintained to within 1/2" (12.7mm).
☆ Work in standard keystone jack opening (0.58" x 0.78" or 14.7mm x 20.1mm).
☆ Unshielded and shielded versions available for choice.
☆ Accept 110 punch down tools or Krone punch down tools.
☆ Color coded for 568A and 568B wiring scheme.
☆ Swept frequency tested up to 150MHz for Cat5e jacks, 300 MHz for Cat 6 jacks and 500 MHz for Cat6A jacks.

1u cable management panel

Technical Parameters:

☆ Made of UL-94V high impact and fire-retardant ABS material. ABS material is characterized by good impact, chemical & fire resistance.UL94V-0 is the highest standard on fire resistance.
☆ Beryllium copper contacts for superior connectivity, with 100μ" nickel baseboard furnished with 50μ" gold plating.
☆ Support 22 -26AWG wire gauge.
☆ Plug Retention Force: 10kg (minimum)
☆ Plug & Keystone Jack Contact Force: 100 g.
☆ Insertion Life Cycle: 1,000 cycles (minimum) / I.D.C 250 cycles (minimum)
☆ Insulation Resistance: 500MΩ
☆ Contact Resistance: 20MΩ
☆ Current Rating: 1.5 Amps
☆ DC Resistance: Max.0.1Ω
☆ Dielectric Withstand Voltage: 1,000VAC RMS @ 60Hz/1 min
☆ Operating Temperature: - 10℃ ~ 60℃
☆ Storage Temperature: -40℃ ~ 70℃

◎ Product Certification

E223921

◎ Product Highlights:

☆Full seal design ensures reliable termination and stability.
☆Supplied with a color coded dust cover for dust and dampness protection.
☆IDC contact design eliminates need to strip individual conductors and ensures reliable termination.
☆With a patented technology, all twists are maintained to within 1/2", improving the NEXT value to a great extent.
☆Dust caps/retention caps offer termination with strain relief.
☆Rear part of the jack printed with EIA 568B pin assignment to ensure fast termination.
☆Being component tested, the jacks can work in harmony with lower class products.
☆Provide extra NEXT margin in support of future gigabit application.
☆Provide fully shielded design to ensure the best screening performance.
☆Toolless design can speed up the installation process and save installation costs.
☆100% full shield design can improve EMI/RFI performance. Shield at the jack rear part can effectively protect IDC termination against EMI interference. They allow flexible grounding for shielded cable for each IDC.
☆Shielded panels incorporate 3℃ 60 stainless steel for full EMI (Electro-magnetic Immunity) shielding required by EN 50173.
☆Compact design can support high density installation.

◎ Transmission Properties:

CAT5e Unshielded Keystone Jack

CAT5e Shielded Keystone Jack

Cat5e Jacks

FREQ (MHz) IL
(dB/100m)
NEXT(dB/100m)
MinimumValue/Typical Value/
Standard Value
ELFEXT (dB/100m)
MinimumValue/Typical Value/
Standard Value
RL (dB/100m)
MinimumValue/Typical Value/ Standard Value
1 0.1 85.0/65.0 80.0/65.0 52.0/30.0
4 0.1 75.0/65.0 71.0/63.1 50.0/30.0
8 0.1 68.0/64.9 66.0/57.0 46.0/30.0
10 0.1 66.0/63.0 64.0/55.1 44.0/30.0
16 0.2 62.0/58.9 60.0/51.0 40.0/30.0
20 0.2 60.0/57.0 58.0/49.1 38.0/30.0
25 0.2 58.0/55.0 56.0/47.1 37.0/30.0
31.25 0.2 56.0/53.1 54.0/45.2 35.0/30.0
62.5 0.3 50.0/47.1 48.0/39.2 29.0/24.0
100 0.4 47.0/43.0 44.0/35.1 26.0/20.0
CAT6 Unshielded Keystone Jack CAT6 Shielded Keystone Jack

Cat6 Jacks

FREQ (MHz) IL
(dB/100m)
NEXT(dB/100m)
MinimumValue/Typical Value/
Standard Value
ELFEXT(dB/100m)
MinimumValue/Typical Value/
Standard Value
RL(dB/100m)
MinimumValue/Typical Value/ Standard Value
1 0.1 85.0/75.0 83.0/75.0 52.0/30.0
4 0.1 80.0/75.0 74.0/71.1 53.0/30.0
8 0.1 77.0/75.0 69.0/65.0 55.0/30.0
10 0.1 76.0/74.0 67.0/63.1 56.0/30.0
16 0.1 72.0/69.9 62.0/59.0 57.0/30.0
20 0.1 72.0/68.0 61.0/57.0 59.0/30.0
25 0.1 69.0/66.0 59.0/55.1 59.0/30.0
31.25 0.11 67.0/64.1 58.0/53.2 56.0/30.0
62.5 0.16 61.0/58.1 52.0/47.2 42.0/28.0
100 0.20 57.0/54.0 48.0/43.1 33.0/24.0
200 0.28 52.0/48.0 42.0/37.1 21.0/18.0
250 0.32 47.0/46.0 40.0/35.1 17.0/16.0

CAT6A shielded Keystone Jack

Cat6A Jacks

FREQ (MHz) IL
(dB/100m)
NEXT(dB/100m)
MinimumValue/Typical Value/
Standard Value
ELFEXT(dB/100m)
MinimumValue/Typical Value/
Standard Value
RL(dB/100m)
MinimumValue/Typical Value/ Standard Value
1 0.1 104.0/94.0 120.0/110 84.0/68.0
4 0.1 92.0/82.0 108.0/98.0 82.0/56.0
8 0.1 86.0/75.9 102.0/91.9 66.0/49.9
10 0.1 84.0/74.0 100.0/90.0 64.0/48.0
16 0.1 80.0/69.9 96.0/85.9 60.0/43.9
20 0.1 78.0/68.0 94.0/84.0 59.0/42.0
31.25 0.11 75.0/64.1 90.0/80.1 54.0/38.1
62.5 0.16 68.0/58.1 84.0/74.1 48.0/32.1
100 0.20 64.0/54.0 80.0/70.0 44.0/28.0
200 0.28 58.0/48.0 74.0/64.0 38.0/22.0
250 0.32 56.0/46.0 72.0/62.0 36.0/20.0
300 0.36 53/42.9 70.0/60.5 34.0/18.5
350 0.41 50/40.2 69.0/59.1 33.0/17.1
400 0.45 48/37.9 68.0/58.0 32.0/16.0
450 0.49 36.0/35.8 67.0/56.9 31.0/14.9
500 0.53 44.0/34.0 66.0/56.0 30.0/14.0